CISPR11/ GB4824: Industrial, scientific and medical (ISM) radio-frequency equipment and similar equipment –Radio-frequency disturbance characteristics –Limits and methods of measurement
CISPR14-1/ GB4343.1:Electromagnetic compatibility . Requirements for household appliances, electric tools and similar apparatus -Part 1: Emission




|
产品名称型号 |
EMI断续干扰(CLICK)SN665 |
|
符合标准及条款 |
|
|
CISPR11/ GB4824: Industrial, scientific and medical (ISM) radio-frequency equipment and similar equipment –Radio-frequency disturbance characteristics –Limits and methods of measurement CISPR14-1/ GB4343.1:Electromagnetic compatibility . Requirements for household appliances, electric tools and similar apparatus -Part 1: Emission |
|
|
试样范围、用途、原理、结构及使用环境 |
|
|
试样及限制 |
家用电器、电动工具、使用半导体装置的调节器、电动医疗设备、诊断用 X 射线发生装置、电动玩具、自动配给机及电影和幻影放映机等,有定时或程序控制的设备 |
|
试验用途 |
在开关切换瞬间会产生比正常工作状态大得多的断续干扰,依据 CISPR 14-1 和 CISPR 11 等标准要求,需要测量断续干扰(又称喀呖声)。 |
|
测试原理 |
喀呖声是指:超过连续干扰的允许值持续时间不大于 200ms,而且后一个干扰离前一个干扰至少为 200ms 的一种干扰。两个间隔时间与连续干扰允许值的电平有关。一个喀呖声可能包含几个脉冲 |
|
结构及特点 |
测试配置布置图: 喀呖声分析仪(或具备喀呖声分析的接收机)、人工电源网络、EMC测试软件等 测试环境:电磁屏蔽室 |
|
使用环境 |
电源:380V±10% 50/60Hz 环境温度: 5℃~+40℃,周围不应有高浓度粉尘、腐蚀性气体和易燃易爆气氛存在 |
|
主要性能指标 |
|
|
主要测试设备 |
喀呖声分析仪(或具备喀呖声分析的接收机)、人工电源网络、EMC测试软件等 |
|
测试环境 |
电磁屏蔽室 |
|
喀呖声发生的频度 |
用喀呖声率N(1分钟内的喀呖声次数)表示,它决定了喀呖声的危害程度。N越大越接近连续骚扰,其幅值限值Lq,应等同于连续骚扰的限值L。N越小危害程度越小,其幅值限值Lg应该放宽 |
|
判断标准 |
EUT产生的喀呖声骚扰是否合格,应按“上四分位法”来确定,即在观察时间内记录的喀呖声如有1/4以上其幅度超过喀呖声限值Lg,则判断产品不合格。 |
|
示意图 |
|
地址:广州市番禺区石壁街道屏山二村屏山工业区三街6号一楼101
电话:18925131363 微信同号
座机:020-39185976
网站:www.sinuotek.com
邮箱:nick@sinuotek.com